Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -1- HA026270
2132 and 2116
PID
Temperature Controllers
Installing and Operating Instructions
Thank you for choosing the 2132 or 2116 Temperature Controller.
Supplied in 1/32 and 1/16 DIN panel sizes they are designed for
accurate, stable control of ovens, chillers, sterilisers and other
heating and cooling processes. Two outputs are configurable for
heating, cooling and alarms.
D
IMENSIONS AND
I
NSTALLATION
Model 2132
Model 2116
E
LECTRICAL
C
ONNECTIONS
The controller is supplied configured according to the order code
given on page 11. Check this on the side labels to determine the
configuration of your particular controller.
To Install the Controller
Please read the safety information on pages 11 & 12 before
proceeding.
1. Prepare the panel cut-out to the size shown
2. Insert the controller through the cut-out.
3. Spring the panel retaining clips into place. Secure the
controller in position by holding it level and pushing both
retaining clips forward.
4. Peel off the protective cover from the display
Unplugging the Controller
The controller can be unplugged from its sleeve by easing the
latching ears outwards and pulling it forward out of the sleeve.
When plugging it back into its sleeve, ensure that the latching ears
click back into place to maintain the IP65 sealing.
Output ratings
Logic Output: 9Vdc, 12mA (non-isolated from sensor input).
Used for: Heating, Cooling or Alarm.
Relay Output: 2A, 264V ac resistive.
Used for: Heating, Cooling or Alarm.
Contact Closure Input (replaces Logic Output).
Used for: Alarm Acknowledge or Timer start/reset
Wire Sizes
The screw terminals accept wire sizes from 0.5 to 1.5 mm (16 to
22AWG). Hinged covers prevent hands or metal making
accidental contact with live wires. The rear terminal screws
should be tightened to 0.4Nm (3.5lb in).
Panel cut-out
24mm
(0.95in)
48mm
(
1.89in
)
103mm
(
4.01in
)
mm
22.22
-
0
.
0
, +
0
.
3
x 45
-0.0, +0.6
Inch
0.88
-
0
.
0
, +
0
.
10
x 1.77
-0.0, +0.02
Latching ears
Panel retaining clips
Recommended minimum
spacing of controllers in
both sizes
10mm
(0.4 in)
38mm
(1.5 in)
(Not to
scale)
45 x 45 mm
-0.0, + 0.6
1.77 x 1.77in
-0.00, +0.02
103mm (4.01in)
Latching ears Panel retaining clips
48mm
(1.89in)
Panel cut-out
48mm
(
1.89in
)
1B
1A
Pt100
T/C
Output 2
Relay
Neutral
Line
Logic
I/O
Model 2132
External Relay Module
(Operated by the logic output)
OR
Solid
State
Relay
(SSR)
2.49
Sensor Inputs
ABV+V-
AA
LN
+
-
mA
Low voltage supply
2424
20-29 Vac/dc
85-264Vac
1B 1A
External Relay Module
(Operated by the logic output)
Model 2116
OR
Solid
State
Relay
(SSR)
+
-
Logic
I/O
Line
Neutral
Output 2
Relay
T/C
Pt100
mA
Sensor Inputs
20-29V ac/dc
Low voltage
supply
L
N
AA
AB
V+
V-
24
24
1A
1B
2.49
85-264Vac
This controller meets the European Directives on safety and
EMC.
Vue de la page 0
1 2 3 4 5 6 ... 12 13

Résumé du contenu

Page 1 - 2132 and 2116

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -1- HA0262702132 and 2116 PID Temperature ControllersInstalling and Operating In

Page 2

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -10-

Page 3 - Press or to view the

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -11-

Page 4 - PARAMETER LISTS

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -12-

Page 5

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -13-

Page 6

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -2- HA026270Typical Wiring DiagramOPERATIONSwitch on the controller. Following a

Page 7

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -3- HA026270TO VIEW THE OUTPUT POWERDo this

Page 8

Issue 2, Nov-98 Applies to software versions 1.3 & 1.4 -4-

Page 9

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -5-

Page 10 - Overshoot

Issue 2, Nov-98 Applies to software versions 1.3 & 1.4 -6-

Page 11

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -7-

Page 12 - Caution:

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -8-

Page 13

Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -9-

Commentaires sur ces manuels

Pas de commentaire