Laboratory Equipment Pty Ltd
Appendix A. Eurotherm 3216/2416/2404 Controller Instructions
1
Appendix A
Eurotherm Controller Instructions
Description of Controls
General
The control panel is fitted with two controls: an ON/OFF SWITCH, and a TEMPERATURE
CONTROLLER.
On/Off Switch
The On/Off switch isolates mains power to the temperature controller and to the solid state relay.
If access to electrical connections inside the equipment is required, ensure that the electrical
power is switched off where the equipment is connected to the main supply.
Temperature Controller
The Eurotherm microprocessor temperature controller has the facility to program a ramp in
°C/seconds/minutes/hours.
Indicator and Button Functions
The Eurotherm controller has the following buttons and indicators:
Indicator
or button
Name
Function
OP1
Output 1
When lit, this indicates that the
element output is on.
OP2
Output 2
When lit, this indicates that an
alarm condition exists.
Page button
Press to select a new list of
parameters.
Scroll button
Press to select a new parameter
in a list.
Down button
Press and release to view the
setpoint or a selected
parameter. Keep pressed to
decrease the value.
Up button
Press and release to view the
setpoint or a selected
parameter. Keep pressed to
increase the value
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Appendix A

Laboratory Equipment Pty Ltd Appendix A. Eurotherm 3216/2416/2404 Controller Instructions 1 Appendix A Eurotherm Controller Instructions Description

Page 2

Laboratory Equipment Pty Ltd Appendix A. Eurotherm 3216/2416/2404 Controller Instructions 2 Display The display normally indicates actual temp or para

Page 3

Laboratory Equipment Pty Ltd Appendix A. Eurotherm 3216/2416/2404 Controller Instructions 3 Error Messages Alarm What it means What to do about it F

Page 4 - Meaning or Function

Laboratory Equipment Pty Ltd Appendix A. Eurotherm 3216/2416/2404 Controller Instructions 4 Tuning In tuning, you match the characteristics of the con

Page 5

Laboratory Equipment Pty Ltd Appendix A. Eurotherm 3216/2416/2404 Controller Instructions 5 AUTOMATIC TUNING TWO AUTOMATIC TUNING PROCEDURES ARE PROV

Page 6 - Temperature

Laboratory Equipment Pty Ltd Appendix A. Eurotherm 3216/2416/2404 Controller Instructions 6 Typical automatic tuning cycle Calculation of the c

Page 7

Laboratory Equipment Pty Ltd Appendix A. Eurotherm 3216/2416/2404 Controller Instructions 7 MANUAL TUNING If for any reason automatic tuning gives uns

Page 8

Laboratory Equipment Pty Ltd Appendix A. Eurotherm 3216/2416/2404 Controller Instructions 8 Example (a) Example (b) Where the temperature appr

Commentaires sur ces manuels

Pas de commentaire