Eurotherm 2132 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Adaptateurs et onduleurs de puissance Eurotherm 2132. - Eurotherm plc Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
IDEAL FOR:
Plastic extrusion
Chillers
Sterilisers
Small ovens
Heat sealing
Trace heating
FEATURES:
Universal input selection
Two configurable outputs
Three internal alarm
setpoints
Heater failure detection
Tactile buttons
Customised operator
interface
PID Temperature Controllers
Specification Sheet
•EUROTHERM® FLEXIBLE SOLUTIONS•
2132
2116
MODELS
Available in compact 1/32 and 1/16 DIN panel sizes, the 2100 Series
uses advanced PID algorithms to give stable ‘straight line’
temperature control.
Self tuning is included to optimise the control performance without
the need for specialist knowledge or training.
Universal Input
A universal input allows selection of nine internally stored
thermocouple types and the Pt100 resistance thermometer.
Other input linearisations may be factory downloaded. Linear inputs
can be scaled to the desired display range.
Outputs
Two outputs are configurable for heating, cooling or alarms.
Alarm Setpoints
Three internal alarm setpoints are provided, configurable as high, low
or deviation alarms. Alarms can be ‘blocked’ on start-up to prevent
unnecessary operator alerts.
Heater Failure
Heater failure can be detected when the controller is used with a
TE10S Solid State Relay.
Operator Interface
The operator interface can be customised to present only those
parameters that an operator needs to see and adjust, while all other
parameters are locked away under password protection.
Tactile buttons ensure positive operation.
Timer Functionality
Temperature
Setpoint
Ramp
Control
T
ime
Dwell Time
Switch off
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Specification Sheet

IDEAL FOR:● Plastic extrusion● Chillers● Sterilisers● Small ovens● Heat sealing● Trace heatingFEATURES:● Universal input selection● Two configurable o

Page 2 - Dimensional details

GeneralEnvironmental performanceTemperature limits Operation: 0 to 55°C Storage: -30 to 75°CHumidity limits Operation: 5 to 95% RH non condensingStor

Page 3 - Rear terminal connections

ORDER CODEStandard Sensor Thermocouple InputsJ J K K T T L L N N - Nicrosil/NisilR R - Pt/Pt13%RhS S - Pt /Pt10%RhB B - Pt/Pt30%Rh -6%RhP Platinel II

Page 4 - Printed on

Eurotherm: International sales and serviceUnderstanding and providing local support is a key part of Eurotherm business. Complementing worldwide Eurot